Homepage | Set Home | Add to Favorites
Member

Dalian Huayi Electric Power Electric Appliances Co., Ltd


Products
  • No Category
Search
 

Friends links
  • No link

110kV Voltage Transformer Inductive Outdoor Electric Substation Equipment
Click image to view full size image
Product: Views:3110kV Voltage Transformer Inductive Outdoor Electric Substation Equipment 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2024-05-21 22:04
  Inquiry
Details
110kV Voltage Transformer Inductive Outdoor Electric Substation Equipment 110kVvoltage transformer/ potential transformer is used in power stations for metering and protection purpose under service ambient temperature of -55?~+50?. Insulation altitude is less than 2000m or according to user’s request. Here we have two options for your selection, cascade and monopole structure Both types we have more than 10 years experience, and all of them have type test reports from independent lab, also we have detailed and strict factory in line and final routine test, we are a traditional manufacturer of instrument transformer, we have a complete production line, most parts are produced by ourselves, so we have price and quality advantages, we are original source, it can be inspected from starting and internal. Our products have been exported to Canada, Pakistan, Armenia,l Albania and so on. Presently we never met any complain from clients, Most of them are with a well operation mode. Product Name 110kV VT Voltage Transformer Inductive Outdoor Electric Substation Equipment Brand Name HYEE Origin China Phase Single Coil Structure Wound Type Cascade / Monopole Color Brown/White Frequency 50/60Hz Certification ASTA/CTQC/IEC/SGS/ISO9001 Package Wooden Carton Delivery Time: 30 days Rated primary voltage, kV Highest voltage for equipment, kV Rated frequency, Hz 50;60 Rated power frequency withstand voltage, kV 140/160 230 275 460 Rated lightning impulse voltage, kV 325/350 550 650 1050 2000 Flashover distance, mm 780 1050 1300 Cree. distance, mm W1:1450 W2:1820 W3:2250 W1:2520 W2:3150 W3:3910 W1:2900 W2:3630 W3:4500 W1:5040 W2:6300 W3:7820 Mechanical load, N 1250 1250 1250 1250 Rated secondary voltage, kV Secondary terminal marks 1a-1n 2a-2n da-dn Accuracy class 0.2 0.5 3P Rated output, VA 100 250 300 150 150 300 150 - 300 Thermal limiting output, VA 2000 Rated voltage factor 1.2continuous; 1.9/8h (66kV) 1.2continuous; 1.5/30s(110~220kV)
link:http://www.hyee-current-transformer.com
Inquiry